6-22 Communications
Registers (Cont'd)
Hardware Configuration (Cont'd)
40313 Gray Level
Read/write
Values: 0 = Positive True, 1 = Negative True
On controllers equipped with the "-G" Option, this register specifies the logic level of the Gray
code bit pattern.
40314 Time Base
Read only
Values: 0 = 1mS, 1 = .5mS, 2 = .2mS
Returns the timer interrupt rate.
40315 Termination Resistor One
Read/write
Values: 0 = Off, 1 = On
Termination resistor On/Off RS485 port; keyboard port for 6000's, RS485 Communication
port for 5144's.
40316 Termination Resistor Two
Read/write
Values: 0 = Off, 1 = On
Termination resistor On/Off for RS232/RS485 port; communication port for 6000's with 5144A
Input Board.
Display Configuration
40317 Default Display
Read/write
Values: 0 = RPM, 1 = Position, 2 = Auto Select
Specifies Pos/Rpm display mode; only applicable on 5XXX controllers.
40318 Rate Multiplier
Read/write
Values: 1 - 1091
RPM rate multiplier; 6000 controllers only.
40319 Rate Divisor
Read/write
Values: 1 - 63
RPM rate divisor, 6000 controllers only.
40320 Rate Decimal Point Position
Read/write
Values: 0 - 3
RPM decimal point position; 6000 controllers only.
40321 Rate Units
Read/write
Values: 0 = RPM, 1 = BPM, 2 = CPM, 3 = IPM
RPM display units; 6000 controllers only.
40322 Toggle RPM
Read/write
Values: 0 - n
Specifies RPM which will cause position display to blank (6000 series) or to change from
Position to RPM (5000 series).
40323 RPM Update Rate
Read/write
Values: 0 = 1/Sec, 1 = 2/Sec, 2 = 10/Sec
Rate at which the RPM display is updated.