
6-5 Communications
CMD
(hex) Name Function
56 Kbd Qty Number of keypads connected.
Put: ! ADR 56 P XX CSM <CR>
Reply: A <CR>
Get: ! ADR 56 G CSM <CR>
Reply: A XX CSM <CR>
where “XX” = number of keypads connected.
0D Setup ID Setup ID code.
Put: ! ADR 0D P XXXX CSM <CR>
Reply: A <CR>
Get: ! ADR 0D G CSM <CR>
Reply: A XXXX CSM <CR>
where “XXXX” = Setup Enable Code in hex.
0E Operator ID Operator ID code.
Put: ! ADR 0E P XXXX CSM <CR>
Reply: A <CR>
Get: ! ADR 0E G CSM <CR>
Reply: A XXXX CSM <CR>
where “XXXX” = Operator Enable Code in hex.
58 Master ID Master ID code.
Put: ! ADR 58 P XXXX CSM <CR>
Reply: A <CR>
Get: ! ADR 58 G CSM <CR>
Reply: A XXXX CSM <CR>
where “XXXX” = Master Enable Code in hex.
0F User Pgm User programming enable/disable.
Put: ! ADR 0F P XX <00 or 01> CSM <CR>
Reply: A <CR>
Get: ! ADR 0F G XX CSM <CR>
Reply: A <00 or 01> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” =
disable, and “01” = enable.
10 Motion Enab Motion detection on/off for a specified output channel.
Put: ! ADR 10 P XX <00, 01, or 02> CSM <CR>
Reply: A <CR>
Get: ! ADR 10 G XX CSM <CR>
Reply: A <00, 01, or 02> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” = L1 &
L2 off; “01” = L1 on; “02” = L2 on.
Configuration
Commands
Serial Commands (cont’d)
Comentários a estes Manuais